R-Type and S-Type Platinum-Rhodium Thermocouple Bare Wire for Precision Research
We offer factory direct pricing and special discounts on bulk orders. Whether you need small or large quantities, our products ship quickly to ensure a reliable supply for industrial projects worldwide. Click the button below to request a quote today!
- Overview
- Specification
- Off-the-shelf supply
- FAQs
- Recommended Products
- R-Type: Platinum (Pt) for the positive leg and Platinum-Rhodium (Pt-13%Rh) for the negative leg.
- S-Type: Platinum (Pt) for the positive leg and Platinum-Rhodium (Pt-10%Rh) for the negative leg.
- Calibration Laboratories: R-Type and S-Type thermocouples are frequently used in calibration labs to ensure that temperature measurement instruments remain accurate. Their stable EMF outputs make them ideal for thermometer calibration and temperature standardization.
- High-Temperature Testing: These thermocouples are used in materials research to study the properties of materials under extreme temperature conditions, helping scientists and engineers to test the behavior of materials in high-temperature environments.
- Cryogenics: Although their primary use is for high-temperature measurement, S-Type thermocouples are also used in cryogenic research to measure temperatures accurately across a wide range.
- Metallurgical and Steel Industries: Used in furnaces, kilns, and casting processes, R-Type and S-Type thermocouples are essential for monitoring the temperature of molten metals, where precise temperature control is vital to maintaining the properties of the final product.
- Aerospace and Aviation: R-Type and S-Type thermocouples are used in jet engines and turbine testing, where they measure the extreme temperatures found in engine combustion chambers. Accurate temperature measurements are crucial for ensuring the performance and safety of aircraft.
- Nuclear Industry: They are used in nuclear reactors to monitor and control the temperature in reactors, where maintaining precise thermal control is crucial for safety and efficiency.
- Metrology Labs: R-Type and S-Type thermocouples are used in high-precision temperature measurement, where they offer exceptional stability and accuracy for the most demanding measurements.
- Research in Energy Systems: These thermocouples are also used in energy research to monitor temperatures in power plants, geothermal energy systems, and other thermal energy applications where high temperatures are common.
R-Type and S-Type thermocouples, made from platinum (Pt) and rhodium (Rh), are highly regarded for their accuracy, stability, and precision in a wide range of demanding research and industrial applications. These thermocouples are particularly valuable in high-temperature environments, where precise temperature measurement is critical. Both R-Type and S-Type thermocouples are well-known for their ability to maintain stability over extended periods, which makes them a preferred choice for scientific research, calibration labs, and high-precision testing environments.
This article provides an overview of the materials, applications, and user needs related to R-Type and S-Type platinum-rhodium thermocouple bare wires used in precision research.
Material Composition and Characteristics
R-Type and S-Type thermocouples are constructed from two high-performance materials:
Key Features
High Temperature Range: R-Type and S-Type thermocouples operate efficiently in extreme temperature ranges, with R-Type thermocouples being capable of measuring temperatures up to 1,768°C (3,214°F) and S-Type thermocouples up to 1,768°C (3,214°F) as well. This makes them ideal for high-temperature applications where other thermocouple types would not perform accurately.
Excellent Accuracy: These thermocouples offer Class 1 accuracy, which can reach ±1.5°C or 0.25% of the reading. This precision is essential for scientific research and calibration applications where even minor temperature deviations could result in significant data errors.
Long-Term Stability: The combination of platinum and rhodium ensures minimal drift in the EMF (electromotive force) output over time, providing stable and reliable measurements even in extreme conditions.
Resistance to Oxidation: Both R-Type and S-Type thermocouples feature superior oxidation resistance, which allows them to maintain their accuracy and functionality in high-oxygen environments, particularly at high temperatures.
Low Drift at High Temperatures: These thermocouples are specially designed to operate in environments with minimal drift in their readings, ensuring that the precision of their measurements is maintained for long periods.
Applications of R-Type and S-Type Thermocouple Bare Wire
Due to their high-temperature resistance and exceptional accuracy, R-Type and S-Type thermocouples are used in a variety of applications that demand precise temperature control and monitoring.
1. Precision Research and Scientific Applications
2. Industrial Applications
3. Advanced Laboratory Settings
Meeting the Needs of Precision Research Users
Users in precision research and high-temperature industries rely on R-Type and S-Type thermocouples for their superior performance and reliability. Here are the key factors that meet the needs of these demanding applications:
1. Uncompromising Accuracy
R-Type and S-Type thermocouples are designed for environments where high accuracy is a non-negotiable requirement. The Class 1 accuracy ensures that users can confidently rely on the readings for critical scientific research, calibration, and testing.
2. Longevity and Durability
In research and industrial applications, it’s important that the thermocouples remain reliable over time. R-Type and S-Type thermocouples are made with platinum-rhodium alloys that exhibit minimal drift in EMF output, ensuring long-term stability even in extreme temperatures.
3. Thermal Response Time
In high-precision applications, fast and reliable thermal response is essential. R-Type and S-Type thermocouples offer fast response times to temperature changes, providing real-time data for applications that require immediate feedback.
4. Wire Gauge and Insulation Options
R-Type and S-Type thermocouples come in various wire gauges, ranging from fine to thick wires, which cater to different applications that require flexible and durable wires. Insulation options are also available, such as ceramic or fiberglass, which provide additional protection in high-temperature environments.
5. Environmental Resistance
These thermocouples are resistant to harsh conditions, making them suitable for use in oxidizing environments and under extreme conditions. Users must still ensure that the correct protective coatings are applied to avoid corrosion in specific settings.

FAQs:
How long is the delivery time?
It depends on the quantity of the order, 10-30 days for small orders. For large orders, it takes 60 days.
Do you accept OEM/ODM production?
Yes! We accept OEM/ODM production. You can send us your samples or drawings.
How do you control the quality of your products? Do the chemical properties of the products meet the quality standards?
With professional quality team, advanced product quality planning, strict implementation and continuous improvement, we will issue product quality inspection certificate, including chemical analysis report.
Can your company provide detailed technical data and drawings?
Yes, you can. Please tell us the products and applications you need, and we will send you detailed technical data and drawings for your evaluation and confirmation.
How do you handle pre-sale and after-sale service?
We have a professional business team who will work one-on-one to protect your product needs, and if you have any questions, he can answer them for you!
Can I visit your factory before placing an order?
Yes, you are welcome to visit our factory. We are glad to have the opportunity to get to know each other.
Where is your production base?
We manufacture our products in Jiangsu, China and ship them from China to your country as soon as possible, which usually depends on your product requirements and quantity.
Can you send samples?
Yes, we can.